I predict, these things will become more prolific…
Solid idea, low-cost, high visibility, easy deployment, and most importantly, an incredible resource during a disaster.
Imagine the possibilities…
@rusnivek
It’s almost lunch…so its a good time to check your winter emergency preparedness kit for these 2 important items
Lunch time learning…just cause I like you.
For more information, check out
http://www.ready.gov/build-a-kit
@rusnivek
Just because it’s a comedic movie, it does NOT mean it will be a funny bit on TV.

IMHO, this CNN HLN parody segment bombed.
Extra kudos to the EP who broke this segment early for a commercial.
Please CNN, stick to just the news.
@rusnivek
Although this kid’s grammar isn’t perfect, I’d take his/her drive and any day.

Embody the job…
…and be proud of your career.
@rusnivek
It’s really amazing to see what areas of ordinary life inspire you.

Everyday surroundings make our life better… But it takes a person with solid situational awareness to discern normal from great.
Today, the crescendo of sounds and lights helped me prioritize and understand life a little better in this great town.
@rusnivek
Fire Training – Roof Operations Course coming up on Saturday January 18th, 2014 from 1330-1730 (C).
http://www.firefighterbailout.com/roofops.html
@rusnivek
Schnikies – it’s December.
And my assignment card seems to be fairly full. This month I’ll be in FEMA Region 10, 8, 9, 3, and of course Region-5.
Also this month, I should be submitting my paperwork for my FEMA Professional Continuity Practioner’s certification.
Looking forward to the change of scenery with my travels this month. As always, any peeps want to catch up or #Tweetup, let me know.
Happy holidays everyone!
@rusnivek
Take a few moments to learn about the now infamous Cold Storage Warehouse Fire in Worcester, Massachusetts.
Honor your fallen Firefighters who gave their life on December 3, 1999.
***In my opinion, this fire is a defining moment in fire service history***
All Firefighters should know about this fire by heart.
Well, even if you don’t read the entire NIOSH report, at LEAST read the summary below.
SUMMARY
On December 3, 1999, six career fire fighters died after they became lost in a six-floor, maze-like, cold-storage and warehouse building while searching for two homeless people and fire extension. It is presumed that the homeless people had accidentally started the fire on the second floor sometime between 1630 and 1745 hours and then left the building. An off-duty police officer who was driving by called Central Dispatch and reported that smoke was coming from the top of the building. When the first alarm was struck at 1815 hours, the fire had been in progress for about 30 to 90 minutes. Beginning with the first alarm, a total of five alarms were struck over a span of 1 hour and 13 minutes, with the fifth called in at 1928 hours. Responding were 16 apparatus, including 11 engines, 3 ladders, 1 rescue, and 1 aerial scope, and a total of 73 fire fighters. Two incident commanders (IC#1 and IC#2) in two separate cars also responded.
Fire fighters from the apparatus responding on the first alarm were ordered to search the building for homeless people and fire extension. During the search efforts, two fire fighters (Victims 1 and 2) became lost, and at 1847 hours, one of them sounded an emergency message. A head count ordered by Interior Command confirmed which fire fighters were missing.
Fire fighters who had responded on the first and third alarms were then ordered to conduct search-and-rescue operations for Victims 1 and 2 and the homeless people. During these efforts, four more fire fighters became lost. Two fire fighters (Victims 3 and 4) became disoriented and could not locate their way out of the building. At 1910 hours, one of the fire fighters radioed Command that they needed help finding their way out and that they were running out of air. Four minutes later he radioed again for help. Two other fire fighters (victims 5 and 6) did not make initial contact with command nor anyone at the scene, and were not seen entering the building. However, according to the Central Dispatch transcripts, they may have joined Victims 3 and 4 on the fifth floor. At 1924 hours, IC#2 called for a head count and determined that six fire fighters were now missing. At 1949 hours, the crew from Engine 8 radioed that they were on the fourth floor and that the structural integrity of the building had been compromised. At 1952 hours, a member from the Fire Investigations Unit reported to the Chief that heavy fire had just vented through the roof on the C side. At 2000 hours, Interior Command ordered all companies out of the building, and a series of short horn blasts were sounded to signal the evacuation. Fire fighting operations changed from an offensive attack, including search and rescue, to a defensive attack with the use of heavy-stream appliances. After the fire had been knocked down, search-and-recovery operations commenced until recall of the box alarm 8 days later on December 11, 1999, at 2227 hours, when all six fire fighters’ bodies had been recovered. NIOSH investigators concluded that, to minimize the risk of similar occurrences, fire departments should
ensure that inspections of vacant buildings and pre-fire planning are conducted which cover all potential hazards, structural building materials (type and age), and renovations that may be encountered during a fire, so that the Incident Commander will have the necessary structural information to make informed decisions and implement an appropriate plan of attack
ensure that the incident command system is fully implemented at the fire scene
ensure that a separate Incident Safety Officer, independent from the Incident Commander, is appointed when activities, size of fire, or need occurs, such as during multiple alarm fires, or responds automatically to pre-designated fires
ensure that standard operating procedures (SOPs) and equipment are adequate and sufficient to support the volume of radio traffic at multiple-alarm fires
ensure that Incident Command always maintains close accountability for all personnel at the fire scene
use guide ropes/tag lines securely attached to permanent objects at entry portals and place high-intensity floodlights at entry portals to assist lost or disoriented fire fighters in emergency escape
ensure that a Rapid Intervention Team is established and in position upon their arrival at the fire scene
implement an overall health and safety program such as the one recommended in NFPA 1500, Standard on Fire Department Occupational Safety and Health Program
consider using a marking system when conducting searches
identify dangerous vacant buildings by affixing warning placards to entrance doorways or other openings where fire fighters may enter
ensure that officers enforce and fire fighters follow the mandatory mask rule per administrative guidelines established by the department
explore the use of thermal imaging cameras to locate lost or downed fire fighters and civilians in fire environments